Lochinvar water heater error codes - • Heater connection wiring supplied with unit. • RTU and serial connect via RS-485 • Ethernet and IP connect via RJ-45 • MS/TP connections type use the XLTR-1000 Gateway 10/19 Printed in U.S.A. Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com ICC-02 ICC Energy Management ...

 
Check the gas type, pressure and volume: Make sure they match the requirements of the unit. Empty the gas line: Bleed all the air from the gas line. Check the size: Make sure the gas line, regulator and meter are the correct sizes. Check connections: Make sure the unit is properly grounded.. Kgbt tv schedule

HTP: Fault Code F13: FAN SPEED ERROR: The fan is not running at the speed that the control has commanded it to run at. The fan speed had been more than 30%...Power Direct Vent Residential Gas Water Heater. Available in 40, 50 and 75 gallon capacities, the models feature a power direct vent system for sidewall or rooftop termination and are qualified for ENERGY STAR. Power Direct Vent Models from 40 to 75 Gallons. Gas Inputs from 40,000 - 72,000 Btu/Hr. Glass Lined Steel Tank with Protective Anode Rod.Lochinvar Copper-Fin II CFN0752 Installation And Operation Manual (80 pages) Lochinvar Water Heater User Manual. Brand: Lochinvar | Category: Water Heater | Size: 7.97 MB.Lochinvar Shield SNR126-065 boiler troubleshooting. - No 120 VAC supplied to unit. • Check external line switch, fuse, or breaker. • Check wiring harness connection between display board and main control board. Connect harness at both points. • Bad display board. • Replace board. - Bad main control board. • Replace the main control board.Inspect the heat exchanger. Reference the Maintenance Section of this manual for the procedure on how to clean the flue side of the heat exchanger. Inspect the flue sensor and associated wiring. Measure the resistance of the flue sensor and compare to Table 3-2D of this manual. Replace the sensor if necessary.Squire Indirect Water Heaters with a dual coil design have a coil in the lower portion of the tank to transfer heat from a solar array to the water that is stored in the tank. An additional coil in the upper portion of the tank will transfer heat from a back-up boiler into the water. This will ensure that the tank has ample hot water even at with water heater. warning all technical and warranty questions: should be directed to the local dealer from whom the water heater was purchased. if you are unsuccessful, please contact the company listed on the rating plate on the water heater. common venting tankless gas water heaters - do not store or use gasoline or other flam- This gas-fired water heater is design certified by CSA International as a Category IV vented heater, under Water Heater Standard ANSI Z21.10.3 • CSA 4.3 (current edition). QUALIFIED INSTALLER OR SERVICE AGENCY Installation and service of this water heater requires ability equivalent to that of a Qualified Agency (as defined by 8 • Residential Standard Gas Water Heater Service Handbook BASICS Scalding Risk A water heater can make water hot enough to cause severe burns instantly, resulting in severe injury or death. Higher temperatures increase the risk of scalding, but even at 120°F, hot water can scald. See Table 2. Thermostatic mixing valves at eachBoilers / Water Heaters / Pool Heaters CH / CF / CP 990-2070 Beginning Serial Number: G936199 to Present Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 615-889-8900 • Fax: 615-882-2918 [email protected] www.Lochinvar.com BY THIS WATER HEATER. Gas Models power vent lvl07580(s), lvn07580(s) wIth hot surface IGnItIon Low Lead Content 300 Maddox Simpson Parkway Lebanon, TN 37090 Phone: 615-889-8900 • Fax: 615-547-1000 Technical Service email: [email protected] www.lochinvar.com. CLICK ANYWHERE on THIS PAGE to RETURN to LOCHINVAR WATER HEATER INFORMATION at ... Yeah, there are different controls depending on the unit age. whats happening is the supply sensor is raising temp to quickly. cause is slow water flow most likely. or if you have motorized isolation valves not opening enough. which is also creating a low flow situation. the supply sensor is a dual sensors. S1 and S9. Electronic Valve Troubleshooting - LochinvarU The Shield commercial gas water heater is a complete water heating system beautifully packaged in a small footprint. 8 Models from 125,000 to 500,000 Btu/hr. High Condensing Efficiency. 5:1 Turndown Ratio. Design Prevents Lime Scale Buildup. SMART CONTROL™ Operating Control with LCD Display and Soft Key Buttons. Technical Documents.ARMOR Condensing Water Heater. With ten models from 400,000 to 4,000,000 Btu/hr input, ARMOR will service a large range of commercial applications and add the "green" touch that building owners and facility managers desire. 10 Models from 400,000 to 4,000,000 Btu/hr. Up to 99% Thermal Efficiency.Installation Commissioning and Maintenance Instructions - LochinvarCode, CAN/CGA-B149.1 and/or B149.2 and/or local codes. This appliance meets the safe lighting performance criteria with the gas manifold and control assembly provided, as specified in the ANSI standards for gas-fired units, ANSI Z21.13. 1. Locate the appliance so that if water connections should leak, water damage will not occur. When such ...Power-Fin® Boilers. Power-Fin boilers continue to evolve with new “Built-in Advantages” from Lochinvar and 85% thermal efficiency. CON•X•US® Remote Connect. Smart Touch Touchscreen LCD Display. 12 Models: 500,000 to 5.0 Million Btu/hr. 5:1 Turndown Ratio. Outdoor Installation Approved. Cascading Sequencer with Cascade Redundancy.Fix issue where Powerfin water heater offset/diff may not have been set correctly from the cloud; Fix a few isolated instances of app crashing; v2.78. Show control panel reboot count on About screen; v2.76. Fix time zones on graph title and axis; v2.75. Fix crash when leaving Service Maintenance screen; Turn the unit back on (if needed) even ... • describe the working principles and layout of the water heater • explain the safety devices • highlight possible hazards • describe the use of the water heater • describe the installation, service and maintenance of the water heater This manual has two parts: • An User part that describes the correct usage of the water heater. Armor X2 AWN1000 water heater pdf manual download. Also for: Armor x2 awn1500, Awl1000, Armor x2awl1300, Armor x2 awn1300, Armor x2 awl1500. ... Lochinvar water heater user manual (36 pages) Water Heater Lochinvar ARMOR 151 - 801 Service Manual ... Do not install the appliance • Local, state, provincial, and national codes, …Armor Water Heater, 1,500,000 Btu/hr input, Natural Gas PM Pump Supplied 10 MODELS FROM 400,000 TO 4,000,000 BTU/HR UP TO 99% THERMAL EFFICIENCY UP TO 10:1 TURNDOWN RATIO DIRECT VENT FLEXIBILITY UP TO 150 FEET W/ CASCADE SEQUENCER REMOTE CONNECT CONDENSING COMMERCIALHeater. Fully modulating, gas fired, tankless water heater specifically designed for residential and commercial applications. 140,000 to 199,000 Btu/Hr Input. Indoor or Outdoor Models. Low Lead Compliant. Low NOx Emissions. SEE MANUAL FOR PARTS LIST. Technical Documents.Summary of Contents for Lochinvar ARMOR 150 - 800. Page 1 AW-SER Rev H Service Manual Models: 150 - 800 This manual must only be used by a WARNING qualified heating installer / service technician. Read all instructions, including this manual and the Armor Water Heater Installation Operation Manual, before installing.Looking for high-quality water heating solution? Review the Product Support: Cyclone® Mxi Condensing Commercial Gas Water Heater with Modulating Burner from A.O. Smith.Water heaters raise the temperature of water for use in bathing, cooking, irrigation, industry and other hot-water applications. Here’s how the three basic types of water heaters w...EFFECTIVE: For 10 Years, Lochinvar warrants the heat exchanger and/or tank against failure due to defects in materials or workmanship. For the lifetime of the product, Lochinvar warrants the tank and/or heat exchanger against failure due to thermal shock. All parts are warranted for 1 year. This limited warranty is in effect when the product is ...Solar Hot Water Generator. Our solar hot water generators provide high-capacity hot water storage for the energy harvested from the sun. Capacities from 120 to 940 gallons. Glass-lined tank. Shipped pre-assembled and tested. Magnesium anodes protect against corrosion.Lochinvar SNA286-125 64 12 Troubleshooting Table 12E Troubleshooting Chart Fault Messages Displayed on Water Heater Interface Installation Service Manual ERROR C... MansIo Mans.Io ContactsLochinvar CPN0752 Installation & Operation Manual (68 pages) Lochinvar Swimming Pool Heater User Manual. Brand: Lochinvar | Category: Swimming Pool Heater | Size: 6.54 MB.MAXXflo Water Heater 3 PAGE SECTION 1 GENERAL AND SAFETY INFORMATION General Information 4 British Standards and Codes of Practice 4 Health and Safety Regulations 1993 4 Legionellae in Water Heaters 5 SECTION 2 TECHNICAL DETAILS Technical Details - CWH30/60/90/120 5 Technical Parameters 6 Product Fiche 7 Heater Dimensions - 200 litre model 7Sep 19, 2023 · To reset a Lochinvar water heater, first turn off the power supply. Then, locate the reset button on the thermostat and press it. After pressing the reset button, turn the power supply back on. Make sure to check if the water heater is functioning correctly after resetting. If the issue persists, you may need to consult a professional. One measurement while the water heater is not firing (static) and again while the water heater is firing (dynamic). If the supply gas pressure drops more than 1.5” W.C. between the static and dynamic pressure measurements, this may indicate the gas line and/or gas regulator to the water heater is undersized.Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com Standard Features >o 99% Thermal Efficiency Up t > Modulating Burner Turndown Ratio 10:1 Turndown AWH0400NPM-AWH1000NPM 5:1 Turndown AWH1250NPM-AWH4000NPM > ENERGY STAR Rated > CON·X·US Remote Connect > Indoor/Outdoor ConvertibleView and Download Lochinvar 100 Series installation & service manual online. Indirect Plate Water Heater. 100 Series water heater pdf manual download. Also for: Ipw120dw, Ipw015dw, Ipw090dw, Ipw070dw, Ipw105dw, Ipw030dw, Ipw050dw.Power Direct Vent Residential Gas Water Heater. Available in 40, 50 and 75 gallon capacities, the models feature a power direct vent system for sidewall or rooftop termination and are qualified for ENERGY STAR. Power Direct Vent Models from 40 to 75 Gallons. Gas Inputs from 40,000 - 72,000 Btu/Hr. Glass Lined Steel Tank with Protective Anode Rod.Pool and Spa Heater. EnergyRite ER152 water heater pdf manual download. Also for: Energyrite er402, Energyrite er252, Energyrite er202, Energyrite er302. ... Lochinvar water heater & boiler replacement parts list (4 pages) Water Heater Lochinvar EW 150 Designer's Manual (28 pages)following the lighting instructions on the water heater ’s. label. Look through the view port for the Pilot flame. If. Pilot is not visible, the spark igniter or gas supply to the. Pilot should be checked. If the Pilot is visible and the Status Light does not blink. after 90 seconds of continuous Pilot operation, the Pilot.Lochinvar CPN501 Installation And Service Manual (60 pages) GAS HEATERS FOR COMMERCIAL POOL APPLICATIONS 500,000 - 2,070,000 Btu/hr MODELS. Brand: Lochinvar | Category: Water Heater | Size: 4.02 MB.ARMOR X2™ Condensing Water Heater. Fully condensing commercial gas water heaters with 96% thermal efficiency. 1 Model - 1.0 million BTU/hr. 96% Thermal Efficiency. 10:1 Turndown Ratio. Less than 20 ppm NOx. SMART TOUCH™ Operating Control with a Built-In Cascading Sequencer.The Lochinvar SSS series indirect water heater (FIG. 1-1) is designed to generate domestic hot water in conjunction with a hot water boiler using forced boiler water circulation. This indirect water heater consists of a 444 Stainless Steel tank in which a smooth 304 stainless steel coil is located.Installation Commissioning and Maintenance Instructions - Lochinvarplace these InstructIons adjacent to heater and notIfy owner to keep for future reference. coMMercIal electrIc water heaters Thank you for buying this energy efficient water heater. We appreciate your confidence in our products. Models ej*006 through ej*020 series 102 es*030 through es*050 series 110 & et*030 through et*120 series 110Is your water heater showing a flammable vapor sensor code? Luckily that error code can easily be reset and you will have hot water again in less then an hou...Generally, Rheem water heaters flicker two light codes- red and blue. For example, blinking the status light 7 times every 3 seconds will indicate different problems determined by the color codes. If the red light flashes 7 times, understand it's the problem with the gas control valve. On the other, blinking blue light indicates the flammable ...These parameters can be changed by the installer by accessing the Set point 1 at High Outdoor Temp 1, Set point 2 at High Outdoor Temp 2 and Set point 3 at High Outdoor Temp 3 parameters. The temperature range of this parameter is 68°F (20°C) to 190°F (88°C). The default value is 70°F (21°C).the water heater. See the Water Connections section of this manual for details. This water heater contains very hot water under high pressure. Do not unscrew any pipe fittings or attempt to disconnect any components of this water heater without positively assuring the water is cool and has no pressure. Always wear protective clothing and with water heater. warning all technical and warranty questions: should be directed to the local dealer from whom the water heater was purchased. if you are unsuccessful, please contact the company listed on the rating plate on the water heater. common venting tankless gas water heaters - do not store or use gasoline or other flam- To access the Night Setback screen press and hold the UP and DOWN buttons simultaneously for 5 seconds. Once pressed the trigger type, On/OFF, should be shown in the upper digits of the display. Use the UP and DOWN buttons to display the desired trigger type, On or OFF and then press ENTER to make selection.This condensing commercial gas water heater is available in five commercial models with inputs ranging from 150,000 to 500,000 Btu/hr. ARMOR features 5:1 modulating turndown, enabling it to fire as low as 20 percent of maximum input and smoothly modulate up to 100 percent depending on demand. ARMOR is also equipped with Lochinvar's SMART ...Have this water heater serviced/inspected by a qualified service technician at least annually. Failure to comply with the above could result in severe personal injury, death or substantial property damage. When calling or writing about the water heater - Please have the water heater model and serial number from the water heater rating plate.Lochinvar Copper-Fin II CFN0752 Installation And Operation Manual (80 pages) Lochinvar Water Heater User Manual. Brand: Lochinvar | Category: Water Heater | Size: 7.97 MB.AFR rods monitor the air fuel ratio of your water heater's internal combustion engine, which is a massively important part of your water heater's function. However, damage and soot can sometimes prevent the AFR rod from doing its job properly and it requires attention.KNIGHT™ Fire Tube Boiler. Consistency in features and benefits across the KNIGHT Fire Tube Boiler family makes it easier to install and service no matter what model you choose. 6 Models from 55,000 to 285,000 Btu/hr. 95% AFUE. Up to 10:1 Turndown Ratio.Table 3-4 Troubleshooting Chart - Fault Messages Displayed on Boiler Interface, Gas Pressure SW, Flow Switch/ LWCO, Blocked Drain SW. 1 48. Download 48 pages, 2.14 …These models display operational and diagnostic information in easy-to-understand words, not codes—and they meet all ASHRAE energy efficiency standards. 10 Models from 5 to 120 Gallons Multiple Voltages and Wattages up to 90 kWThis heater is a 480 volt, 3 phase, 45 KW, 82 gallon Standard Hi-Power model with surface mounted thermostats. (Reprint HP-16 12/08) 5M-10/10 Printed in U.S.A. Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000 www.Lochinvar.com HP-16 Model Gallon GPH @ Number of ShippingThis gas-fired water heater is design certified by Underwriters Laboratories Inc. under American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.3 • CSA 4.3 (current edition). QUALIFIED INSTALLER OR SERVICE AGENCY Installation and service of this water heater requires ability equivalentAug 2, 2023 · August 2, 2023. Home Type Water Heater. Yes, lochinvar is a reliable and highly rated water heater brand. With advanced features and durable construction, lochinvar water heaters provide efficient and consistent performance for your hot water needs. Offering a wide range of models and options, lochinvar ensures that you can find the perfect ... Power Direct Vent Residential Gas Water Heater. Available in 40, 50 and 75 gallon capacities, the models feature a power direct vent system for sidewall or rooftop termination and are qualified for ENERGY STAR. Power Direct Vent Models from 40 to 75 Gallons. Gas Inputs from 40,000 - 72,000 Btu/Hr. Glass Lined Steel Tank with Protective Anode Rod.HEAT EXCHANGER ACCESS AND CLEANING. (5:22) This tutorial will explain how to access and clean the heat exchanger on the Shield Water Heater. DOWNLOAD. Instructions for downloading video files to your device. iPad using a MAC with iTunes. iPad using a PC with iTunes.All KNIGHT fire tube boilers allow for flexible installation with a universal vent connector. Range in heating capacity from 55,000 to 399,000 Btu/hr and perform at 95% AFUE efficiency. The KNIGHT's Smart System™ display includes the CON•X•US® Remote Connect option to maintain control of your boiler from anywhere.Any time an error, fault or function code is displayed, service will be required. Please Note: Any failure of the heat pump will result in an automatic switch to the resistance heat mode to ensure a constant supply of hot water. For service and support on the GeoSpring Hybrid Electric Water Heater, please contact 1-888-443-4394, Monday - Friday ...How to Purchase a FV Sensor from U.S. Water Heating Solutions. 1. Gather the model and serial number of your unit. 2. Contact Us: a. Click the Messenger icon and send us your contact info along with the model and serial number of your unit. b.COMMERCIAL GAS WATER HEATERS LIGHT DUTY CHARGER GAS MODELS Lochinvar's commercial Light Duty Charger tank-type water heaters are available in 55, 74, and 98 gallon capacities. ... Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com For technical information call 800-722-2101 ...This gas-fired water heater is design certified by CSA International as a Category IV vented heater, under Water Heater Standard ANSI Z21.10.3 • CSA 4.3 (current edition). QUALIFIED INSTALLER OR SERVICE AGENCY Installation and service of this water heater requires ability equivalent to that of a Qualified Agency (as defined byHow to fix it: Check that pool pump is receiving enough water. Ensure that your pool pump is sending water to the heat pump. For variable speed pool pumps, try putting the pump speed up a notch Check for any clogs or backups causing poor water circulation. The same is true if what you use is in your pool is the Raypak pool heater. This gas-fired water heater is design certified by CSA International as a Category IV vented heater, under Water Heater Standard ANSI Z21.10.3 • CSA 4.3 (current edition). QUALIFIED INSTALLER OR SERVICE AGENCY Installation and service of this water heater requires ability equivalent to that of a Qualified Agency (as defined by Hot Water Solutions Since 1939 | Lochinvar | LochinvarRefer to the Water Connections Section of. Manuals / Lochinvar / Household Appliance / Water Heater Lochinvar 402, 2072 Troubleshooting continued, Fault, Description, Corrective Action, Service BlkHome / Lochinvar / Water Heater / SNR201-100. Lochinvar SNR201-100 download instruction manual pdf. Category: Climate Equipment. Group: Water Heater. Device: Lochinvar SNR201-100. Instructions and files. ... click on the "Download" button and you will be redirected to a page where you will need to enter the code from the image. If the answer is ...If A is 1964, then B would be 1965, and so on. In conclusion, once you know the letter code in the serial number, figuring out how old your Lochinvar water heater is is simple. With the help of this knowledge, you can properly maintain your water heater, handle warranty issues, and solve any problems that may arise.To reset a Lochinvar water heater, first turn off the power supply. Then, locate the reset button on the thermostat and press it. After pressing the reset button, turn the power supply back on. Make sure to check if the water heater is functioning correctly after resetting. If the issue persists, you may need to consult a professional.CommerCial gas water heaters instruction manual PRINTED 1112 324478-000 plaCe these instruCtions adjaCent to heater and notify owner to keep for future referenCe. Thank you for buying this energy efficient water heater. We appreciate your confidence in our products. models Cln120080, Cln154080, Cln180100, Cln199100, Cln250100(a) ultra low nox ...If you own a Whirlpool washer, you may have encountered error codes at some point during its operation. These error codes can be frustrating, but they serve an important purpose in...LIMITED RESIDENTIAL WATER HEATER WARRANTY ... plumbing, housing or building codes, or II) without a certified American Gas Association, ASME, or comparable combination temperature ... Lochinvar, LLC. • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000 www.Lochinvar.com RES-WAR-06Download 1048 Lochinvar Water Heater PDF manuals. User manuals, Lochinvar Water Heater Operating guides and Service manuals.The SHIELD water heater boasts a 5:1 turndown ratio and can fire at as low as 20% input and increase to 100% at peak demand. Monitor your SHIELD heater with optional CON•X•US® Remote Connect to get alerts on changes in your system's status. Seven venting options allow installers to set up the SHIELD water heating system with ease.Since Rinnai water heaters are one of the most advanced tankless water heaters available, we recommend to contact a service technician that's authorized to work on Rinnai water heaters. Each Rinnai unit uses a temperature controller (either MC-91-1 or MC-91-2) on the front panel to display various configuration options for installation as ...The E351 code specifically signals an issue linked to the air pressure switch within your water heater. The air pressure switch acts as a protective sentinel, monitoring pressure levels inside the combustion chamber to safeguard against potential risks. A problem within this crucial system component can disrupt your heater’s normal operation ...Hot Water Solutions Since 1939 | Lochinvar | LochinvarThis indirect-fired water heater is appropriate for all potable heating systems, even where a single-wall exchanger is not approved by the authority having jurisdiction. ADJUSTABLE THERMOSTAT - The temperature may be adjusted from approximately 80°F to approximately160°F. The thermostat is factory set at 120°F.Lochinvar GTN04040 - 40 Gallon - 40,000 BTU Energy Saver Residental Water Heater (Nat Gas)- Standard Features: Code Compliance - The Energy Saver residential gas water heater meets the National Appliance Energy Conservation Act (NAECA) Energy Factor requirements effective April 16, 2015. Meets the thermal efficiency and standby loss …This video covers the repair of the leaking union above the pump on the lockinvar commercial water heaters .#plumbing #water heater #commercial water heater15-150 psi Water Pressure. 40 psi or above is recommended for maximum flow. *Current numbers based on factory testing; 0.5 gpm required for activation; 0.4 gpm required for continuous fire after initial ignition.

The Lochinvar Copper-Fin II is one of the most advanced water heaters on the market. Its innovative design features gasketless heat exchangers, glass-lined headers, and copper-finned tubes. The units meet ASME construction standards and come with a ten-year limited warranty. This copper-fin boiler offers 85% thermal efficiency, which …. Farmington hills obituaries

lochinvar water heater error codes

Nov 9, 2022 ... ... code SURVIVAL at checkout 00:17 Lochinvar boiler flame failure problem 00:52 History of what's been done so far 01:35 fast access to the ... The bottom of the boiler has a 3/4 inch pipe for connection of a 3/4 inch PVC pipe (FIG. 2-2). Slope condensate tubing down and away from the boiler into a drain or condensate neutralizing filter. Condensate from the Cadet boiler will be slightly acidic (typically with a pH from 3 to 5). Install a neutralizing. Feb 21, 2023 ... Comments12 ; Lochinvar Noble Boiler Service! #hvac #boiler #heating #lochinvar. Jeff's HVAC Adventures · 4.6K views ; Lochinvar Noble Boiler ...Boilers / Water Heaters / Pool Heaters CH / CF / CP 990-2070 Beginning Serial Number: G936199 to Present Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 615-889-8900 • Fax: 615-882-2918 [email protected] www.Lochinvar.comThis procedure is explained in the manual but it is a lot easier if you can just watch somebody do it. You can temporarily change the settings for the temper...View and Download Lochinvar PVL 07575 installation and operating manual online. POWER VENTED GAS WATER HEATERS SERIES 210/211. PVL 07575 water heater pdf manual download. Also for: Pvn 07575, Cvn075075, Cvl075075.Fix or replace the water heater thermostat. 4. Descale the water heater. 5. Fix or replace the faulty pressure valve. The first step to solving any water heater issue, including the beeping noise, is to detect the core issue. Here are some of the most common problems that could be causing your water heater to beep. 1.Knight gas-fired, floor-standing, storage water heaters can achieve efficiencies up to 79% gross CV. These water heaters are designed on the principles of low storage and fast recovery, and when compared to indirect hot water systems, they can achieve savings on energy consumption & carbon emissions. 5 models suitable for Natural Gas or LPG.Veritus Air Source Commercial Heat Pump Water Heater and Thermal-Stor Tank. The best way to get the most out of your Veritus heat pump water heating system is to maintain stored hot water at the desired temperature. Thermal-Stor, with its patent-pending baffle, keeps water steady, stratified and ready for delivery.ERROR 001 - This code hints at a flow or pressure anomaly in the water system. ERROR 002 - A signal that points towards troubles in the venting setup. ERROR 003 - Indicates issues concerning the igniter or flame sense rod. ERROR 004 - Typically associated with problems in the gas supply or combustion mechanism. Have this water heater serviced/inspected by a qualified service technician at least annually. Failure to comply with the above could result in severe personal injury, death or substantial property damage. When calling or writing about the water heater – Please have the water heater model and serial number from the water heater rating plate. July 2014. Hello, I have a Lochinvar Shield Commercial Water heater giving me problems. Model SNA400-125, installed three years ago. It keeps locking out on manual reset high limit when demand is at its lowest at night. I have replaced the inlet and outlet temperature sensors, problem still there. Doent happen every night, it will run good ...Replacing a water heater can be a daunting task, but with the right knowledge and preparation, it can be a smooth process. However, there are some common mistakes that homeowners o....