Head pressure hvac - I settled on an Aspen Coil that was 20" tall, 4 row coil with the higher fin count of the two they offered. It's just a rental, so we stayed with the fixed orifice to save cost. It's got a .080 piston in it. The 3.5 ton we took out was a .078 but it was 10 seer. Now on startup, my head pressure at 87 degrees outside was at 225 or so.

 
Various experts and professionals claim that head pressure for a 410A system should be 400 to 418 PSIG on the high side while 120 to 130 PSI on the lower side. Anything more than this range is considered high head pressure. This value may vary a little bit depending on the weather and other external conditions.. 2018 ford explorer water pump

Head pressure in HVAC refers to the force that keeps refrigerant flowing smoothly through the system. It is essential for optimizing performance and energy efficiency. Understanding head pressure is crucial for troubleshooting and resolving …The most common causes of pressure in the head and face include allergies, ear infections, the common cold, muscle tension, sinusitis, stress and tension headaches. Increased intra...Pressure in the head and neck. The stress in the nerves and muscles of the neck can cause pain in the head. Sometimes, pressure or pain appears in both the head and the neck. This can be caused by ...Head pressure is a critical factor in HVAC (Heating, Ventilation, and Air Conditioning) systems. It refers to the pressure exerted by the refrigerant in the condenser coil, and it is measured in pounds per square inch (PSI).Liebert High Head Pressure lockout. Today customer claims Liebert mini-mate has been locking out on high head pressure once or twice a month, sometimes more often, since it was installed approx. 1 year ago. The company that installed it has come out several times to check it out but found no high pressures. I decided to take the high …Head pressure 190 Suction Pressure 90 Suction line temp 54 inside temp 75 wetbulb 69 So ive been thru this problem b4 with the low head high suction so i assume piston or a-coil . I open up the duct and the other hvac guy has put in a 3ton acoil . I told the neighbor that he should replace the acoil with a 2 1/2 ton .Suction fluctuating pressure was 70 - 74 PSIG. Fluctuation is immediately following start up. Superheat was low about 7F. Subcooling was high like 35F. My first impression was maybe it was overcharged so I recovered about 1 and 1/2 pounds. It brought the head pressure down to a fluctuation of 195 -> 225. Suction pressure to 69 …Jul 5, 2019 ... ... pressure range of what a R410A air conditioner pressures should be. Note that in order to handle or work with refrigerant you need to be ...An HVAC technician taking a static pressure measurement. STEP 2: Drill test ports using a 3/8′ drill bit with a metal piercing tip. A bullet-tip drill makes a clean round port. So make sure to use your drill bit sheath (described above) to help prevent you from drilling into the coil.Undercharged. Can lead to low head pressure. Overcharged. Can lead to high head pressure. Understanding Overcharged Systems When too much refrigerant is crammed into your AC system, a few detrimental things happen: Excess Liquid: Overcharged systems usually have an excess of liquid refrigerant flowing into the compressor.The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.Troubleshooting Refrigerant Charge to Determine a Bad TXV. If your suction pressure is staying the same while adding refrigerant, and your head pressure is shooting up while the suction pressure is staying the same, your TXV valve is probably bad. If you do your homework and suspect that the TXV bulb lost charge, it’s probably a better idea ...Totalinefi Head Pressure Controls The Totalinefi P251-0083C Solid State Head Pressure Control Designed specifically for HVAC and Refrigeration applications, the P251-0083C is a temperature-sensitive fan motor speed control which regulates head pressure at low ambients by varying the air volume through the condenser. Its unique constructionFeb 19, 2022 ... Pressure-balanced, modulating valve provides precise control of head pressure on open or closed refrigeration systems. The water regulating ...Suction pressure and head pressure are directly proportional, and compression ratios remain close to constant roughly 3 to 1 for older A/C systems. So with 60# suction or 75 psia at 3 to 1 compression you get 225 psia head pressure, raise that return temp and get suction pressure up to 85# or 100 psia you get 300 psia.Jun 6, 2020 ... In this video, I show how a Liquid Line Restriction Affects The Liquid Pressure and Subcooling ... What Should my AC Pressures Be for R410A ...The Two Condenser Head Pressure II Module is designed to work stand-alone by using its OPTIONS dip switch to adjust the Head Pressure setpoint. The Two Condenser Head Pressure II Module is directly connected to the VCM-X Modular E-BUS, VCM-X WSHP E-BUS or SA E-BUS Controller, allowing the Module(s) to receive setpoints from the …Originally Posted by CircusEnvy. If the heat recovery unit is installed on the return side of the air handler, pushing hot air against the indoor coil will most certainly cause the head pressure to skyrocket in heat mode. If the heat recovery unit is on the supply side, then this isn't an issue whatsoever.Head pressure, also referred to as discharge pressure, is a vital component of the refrigeration cycle in an HVAC system. It is the pressure exerted by the refrigerant in the condenser as it transforms from a high-pressure gas to a high-pressure liquid, following compression in the compressor.The high head pressure is caused in most of the cooling systems. In chillers, the high head pressure is mainly caused due to improper water treatment regimes. The clogging of the coils can cause high head pressure in the chiller. The condenser water loop is open to the atmosphere in the chiller. The dirty particles are concentrated with the ...0 suction pressure. Got a stumper, atleast for me. Split system, 410a, got to the scene with compressor out on thermal overload. Got it running for 30 seconds or so, noted that head pressure was holding steady but 0 suction pressure. Again compressor went out on thermal. Cooled it off, set up some 410a to add once comp. started running.This video explains what determines head pressure in refrigeration systems. Its explained by a Dunwoody College of Technology staff member Tom Kleinman.The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.Greetings, I am working on a R22 Lennox Split Heat Pump 3 ½ ton. The unit will trip on the compressor relief valve in heating. I was unable to test the unit S/C and S/H accurately, due to the High Side pressure building up so fast with in a minuet will be hitting 400psi and blow the low side would sit at about 50psi. I tested the RVR from cooling to …Job opportunities in HVAC are projected to grow 15 percent between 2016 and 2026, according to the United States Department of Labor. That’s a better outlook than many other occupa...condenser cycles off, the water regulating valve should. Click the card to flip 👆. a. remain open during the off cycle. b. close, since the head pressure is lower. c. open all the way to remove any residual heat. d. re-calibrate itself to maintain the new lower head pressure. ANSWER :B. Click the card to flip 👆.What are A/C system design conditions while running? 95°F outside, 75°F inside, humidity 50%. T or F - The inside relative humidity adds a significant load to the evaporator coil and must be considered part of the load. True. If the outside temperature increases, what happens to the head pressure and system capacity?So the refrigerant volume is less and when the unit is heating and needs less refrigerant, a smaller indoor coil can cause a high head pressure especially if mild out. We use a lot of ADP coils but never on heat pumps. Always use the factory specified coil for this reason. But that's high pressure trips.High suction pressure normal head pressure: When the refrigerant is flowing in the suction line from the compressor to evaporator coil without any leakage or damaging the compressor’s piston and also there no impurities are present then the pressure range will be inside the system is 0.75 – 1.3 MP ,this called the High suction …0 suction pressure. Got a stumper, atleast for me. Split system, 410a, got to the scene with compressor out on thermal overload. Got it running for 30 seconds or so, noted that head pressure was holding steady but 0 suction pressure. Again compressor went out on thermal. Cooled it off, set up some 410a to add once comp. started running.Suction fluctuating pressure was 70 - 74 PSIG. Fluctuation is immediately following start up. Superheat was low about 7F. Subcooling was high like 35F. My first impression was maybe it was overcharged so I recovered about 1 and 1/2 pounds. It brought the head pressure down to a fluctuation of 195 -> 225. Suction pressure to 69 -> 72.Over time, refrigerant can leak out of an air conditioning system, keeping it from doing its job. A Freon recharge is a very common AC repair, though if you need one, there’s probably also a leak somewhere that needs repairing. The average refrigerant refill cost is $200–$640 for a central AC unit, though fixing the leak may cost more.Check the Condenser Fan. The condenser fan generates airflow through the condenser coil. If the condenser fan doesn’t spin, then the condenser coil won’t reject heat properly and your AC high pressure switch will trip. Check the condenser fan to make sure that it spins when the condensing unit kicks on.Feb 19, 2022 ... Pressure-balanced, modulating valve provides precise control of head pressure on open or closed refrigeration systems. The water regulating ...In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...Pump head pressure basics, learn why pumps read pressure in height and call it head pressure.Learn more here ️ https://theengineeringmindset.com/pump-head-...Greetings, I am working on a R22 Lennox Split Heat Pump 3 ½ ton. The unit will trip on the compressor relief valve in heating. I was unable to test the unit S/C and S/H accurately, due to the High Side pressure building up so fast with in a minuet will be hitting 400psi and blow the low side would sit at about 50psi. I tested the RVR from cooling to …How to diagnose high head pressures at the air conditioning or heat pump compressor: What are the causes of high head pressure at an air conditioner or heat pump compressor motor? This article lists twelve causes of high head pressure and explains their causes, effects, and diagnosis.High suction pressure normal head pressure: When the refrigerant is flowing in the suction line from the compressor to evaporator coil without any leakage or damaging the compressor’s piston and also there no impurities are present then the pressure range will be inside the system is 0.75 – 1.3 MP ,this called the High suction …The most common causes of pressure in the head and face include allergies, ear infections, the common cold, muscle tension, sinusitis, stress and tension headaches. Increased intra...Took a reading off one of our units that cool an elevator machine room. It's an old Carrier 10 ton unit, single compressor, water cooled tube in tube condenser. Suction pressure was good at 68 , head pressure went over 300 and was tripping it out. Cleaned the strainer, same thing happens. Brought in a mechanic who says the TEV is bad and …Whether looking to help relieve pain or inflict it, pressures points exist throughout the human body, from the temples to the ankles and feet. For headaches, move your fingers in c... The Two Condenser Head Pressure II Module is designed to work stand-alone by using its OPTIONS dip switch to adjust the Head Pressure setpoint. The Two Condenser Head Pressure II Module is directly connected to the VCM-X Modular E-BUS, VCM-X WSHP E-BUS or SA E-BUS Controller, allowing the Module(s) to receive setpoints from the Controller. When ... The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice.Physical Properties Of R22. In parallel to using the R22 PT chart, professionals will usually need to know some of the following R22 physical properties: R22 liquid density at -69°C: 1.49 g/cm 3. R22 gas density at 15°C: 3.66 kg/m 3. Triple point temperature: -115.76K. Critical pressure: 49.36 bar. Heat capacity ratio at 86°F: 1.178253.Head pressure: 400 lbs. Condenser air in: 140º F. I guess Condenser air out: what; about 160º F. I am guessing? LSC is: 30º F. - so the system has plenty of refrigerant in it Suction Pressure: 105 lbs. Suction Line Temp: 65º F. SSH: 30º - so the evaporator does not have enough refrigerant in it. What am I missing? PHM-----So the refrigerant volume is less and when the unit is heating and needs less refrigerant, a smaller indoor coil can cause a high head pressure especially if mild out. We use a lot of ADP coils but never on heat pumps. Always use the factory specified coil for this reason. But that's high pressure trips.410A System with high head. I went to do a maintenance on a 410A Trane system today, when I came up on the trane I noticed it was running like a 450 pound head pressure, the first thing i thought was why in the world would it be so high, so I cleaned the cool, checked filters, checked txv bulb position, everything checked out although there ... Troubleshooting Refrigerant Charge to Determine a Bad TXV. If your suction pressure is staying the same while adding refrigerant, and your head pressure is shooting up while the suction pressure is staying the same, your TXV valve is probably bad. If you do your homework and suspect that the TXV bulb lost charge, it’s probably a better idea ... On 2019-01-24 by Rkg1963 - Nordyne heat pump head pressure shuts the system down at 600 in heat mode. Have a 3 ton Nordyne Residential HeatPump Condenser that the head pressure run up around 600 before it shuts down . Only in Heat mode. Pressures look great in Cool mode. Any ideas as to why this is? On 2017-11-01 by DavidThe two most common causes of low head pressure at an air conditioner or heat pump compressor motor are: Refrigerant under-charge, due to a refrigerant leak or improper charge. TXV (TEV) malfunction, over-metering refrigerant. This condition is not likely to occur on smaller air conditioners or heat pumps that use a capillary tube to meter ...Head pressure, also referred to as discharge pressure, is a vital component of the refrigeration cycle in an HVAC system. It is the pressure exerted by the refrigerant in the condenser as it transforms from a high-pressure gas to a high-pressure liquid, following compression in the compressor.As an HVAC technician or someone interested in air conditioning systems, understanding the key factors that impact 410A refrigerant pressures is crucial. The proper functioning of ...Mar 25, 2024 · Head pressure is normally the pressure that a compressor makes in air conditioning, refrigeration, and heating systems. Head pressure in a normal range is not an issue, but a high head pressure is always an issue for your system. The compressor in an HVAC system has a very crucial role. It circulates the refrigerants throughout the system such ... The Two Condenser Head Pressure II Module is designed to work stand-alone by using its OPTIONS dip switch to adjust the Head Pressure setpoint. The Two Condenser Head Pressure II Module is directly connected to the VCM-X Modular E-BUS, VCM-X WSHP E-BUS or SA E-BUS Controller, allowing the Module(s) to receive setpoints from the Controller. When ...Air and gasses tend to dissolve more at higher pressure and come out of solution at lower pressure. If you have an expansion tank on a loop in a ...If you are wanting to maintain 180 psig. head pressure the controls would be set as follows: Cut-in Cut-out. Fans 1-2 180 psig. 160 psig. Fans 2-4 200 psig 190 psig. As you can see, this causes fluctuation of the head pressure and can result in expansion valve hunting and poor superheat control.Compression ratio is the ratio of head pressure to suction pressure in an HVAC/R unit. Generally, compression ratios approach 2.5:1 on high-efficiency, 16+ SEER A/C systems. The highest compression ratio in A/C compressors is typically 11:1. Refrigeration compression ratios tend to be quite a bit higher (up to 26:1).Welcome to HVAC-Talk.com, a non-DIY site and the ultimate Source for HVAC Information & Knowledge Sharing for the industry professional! ... Is fluctuating head pressure a sure sign of non condensables? Usually, but not 100% of the time. Reply . 07-04-2013, 11:32 AM #7. Core_d. View ProfileSo the refrigerant volume is less and when the unit is heating and needs less refrigerant, a smaller indoor coil can cause a high head pressure especially if mild out. We use a lot of ADP coils but never on heat pumps. Always use the factory specified coil for this reason. But that's high pressure trips.Typical Low Side Pressure Range for R410A in the field: 115-120 psi. Typical High Side Pressure Range for R410A in the field: 410-420 psi. By 2025, high Global Warming Potential (GWP) refrigerants with a GWP of over 750, will be banned together with the systems using that gas. R410A has a GWP > 2,000.In air conditioning applications, compression ratios of 2.3:1 to 3.5:1 are common, with ratios below 3:1 and above 2:1 as the standard for modern high-efficiency air conditioning equipment. In a 404a medium-temp refrigeration (cooler) application, 3.0:1 – 5.5:1 is a common ratio range.The high side guage was connected to the liquid line. Static, both guages are 160 psig. When the unit ran, BOTH guages dropped to about 130. The high side was perhaps 2-5 higher. The amp draw at the compressor was 8.6 RLA out of a 22.1 suggest maximum on the equipment sticker.Lennox Learning Solutions teaches you what causes high head pressure on a heat pump in the heating mode.There is several factors that can cause hight pressur...As energy costs continue to rise, many homeowners are looking for ways to reduce their energy bills. One of the most effective ways to do this is by taking advantage of government ...Are you looking to enhance your skills in the HVAC industry without breaking the bank? Look no further. In this article, we will explore the best free HVAC classes available to hel...To replace a defective low-ambient control valve with a pressurized dome charge, follow the steps below: 1. Recover the refrigeration system’s refrigerant; 2. Cut the process tube on the valve’s charged dome to remove the pressure charge (wear safety glasses); 3. With a torch, heat the valve until the solder melts; 4.Originally Posted by Andhen. 30 because 30 degrees subcooling. A saturated head pressure 30°F above outdoor temp, doesn't get you 30°F of subcool. While 8 and 10 SEER A/Cs did often have to run 30° saturation over outdoor temp, you still only had 8 to 12° of subcool. Charge by subcool, or by superheat.head pressure will result in low suction pressure and/or iced evaporator coils. The primary off-cycle problem is the possible inability to get the system on-line if the refrigerant has migrated to the condenser. The evaporator pressure may not build up to the cut-in point of the low pressure control and the compressor can’t start even though refrigeration is …Mar 1, 2022 · Head pressure is generated by your gas compressor and can be too high or too low depending on the weather, condensing temperature range, and other factors. Learn how to detect, prevent, and repair high head pressure in your HVAC unit with tips from Home Inspection Geeks. HPCV/ head pressure control valve / head master, help the air conditioning unit maintain normal operating pressures during colder outdoor temperatures below ...Low suction pressure and high head pressure is a condition where there is a decreased refrigerant pressure in the AC system and at the same time a high output pressure in a compressor. This condition is mainly caused by a defective or malfunctioning TXV valve. An expansion valve is a device that regulates the flow of the liquid refrigerant into ...Whether looking to help relieve pain or inflict it, pressures points exist throughout the human body, from the temples to the ankles and feet. For headaches, move your fingers in c...This video explains what determines head pressure in refrigeration systems. Its explained by a Dunwoody College of Technology staff member Tom Kleinman.Feb 26, 2022 · The high head pressure is caused in most of the cooling systems. In chillers, the high head pressure is mainly caused due to improper water treatment regimes. The clogging of the coils can cause high head pressure in the chiller. The condenser water loop is open to the atmosphere in the chiller. The dirty particles are concentrated with the ... OPERATING PRESSURE POINTS “Systems using R-410A operate at higher pressures [than R-22],” points out the Field Diagnostics team. “For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 …On 2019-01-24 by Rkg1963 - Nordyne heat pump head pressure shuts the system down at 600 in heat mode. Have a 3 ton Nordyne Residential HeatPump Condenser that the head pressure run up around 600 before it shuts down . Only in Heat mode. Pressures look great in Cool mode. Any ideas as to why this is? On 2017-11-01 by DavidIts a RPPL. Head pressure slowly climbs to above 600, suction pressure is normal not low at all. Airflow inside is okay... static pressure is .7inWc. Coils are clean. In cooling mode the charge looks damn near perfect... 11 degrees subcooling and 9-11 degrees superheat. The unit has a compensator. I'm stumped.Jun 30, 2023 ... In this video I visit a tenant house I've been to before because it wasn't keeping up! #hvacguy #hvaclife #hvac #hvactrainingvideos ...Technically, "head pressure" is compressor discharge pressure. This pressure is formed by compressing superheated refrigerant vapor and discharging the vapor into the condenser. True "head pressure" is measured at the discharge side of the compressor, not at the liquid line service valve such as on most split systems.As energy costs continue to rise, many homeowners are looking for ways to reduce their energy bills. One of the most effective ways to do this is by taking advantage of government ...This one compares the head pressure and condensing temp of the a/c under light and heavy loads. This video is part of the heating and cooling series of trai...Head pressure in HVAC systems is a critical factor for efficient operation, reflecting the pressure at which the refrigerant is condensed into a liquid. Properly managing head pressure ensures the longevity and efficiency of your HVAC system, reducing the likelihood of breakdowns and energy waste.HVAC systems are intricate, with several components working together to regulate temperature, humidity, and air quality. One crucial aspect of HVAC systems that ensures their proper operation is “head pressure.” In this blog, we will delve into the concept of head pressure in HVAC systems, its significance, and how it affects the cooling ...When it comes to upgrading your shower experience, one of the key factors to consider is water pressure. If you’re looking for a high-pressure shower, you might be torn between cho...

To replace a defective low-ambient control valve with a pressurized dome charge, follow the steps below: 1. Recover the refrigeration system’s refrigerant; 2. Cut the process tube on the valve’s charged dome to remove the pressure charge (wear safety glasses); 3. With a torch, heat the valve until the solder melts; 4.. Reno motorcycle shops

head pressure hvac

Low Ambient, Condenser Flooding, and Headmaster Valves. In this podcast episode, Jeremy Smith comes on the podcast to talk about low-ambient controls, headmaster valves, charging, and condenser flooding. If our head pressure drops too much, we won't get enough of a pressure drop across the TXV. Pressures dictate the TXV function, so we …Air and gasses tend to dissolve more at higher pressure and come out of solution at lower pressure. If you have an expansion tank on a loop in a ...Originally Posted by Andhen. 30 because 30 degrees subcooling. A saturated head pressure 30°F above outdoor temp, doesn't get you 30°F of subcool. While 8 and 10 SEER A/Cs did often have to run 30° saturation over outdoor temp, you still only had 8 to 12° of subcool. Charge by subcool, or by superheat.Welcome to HVAC-Talk.com, a non-DIY site and the ultimate Source for HVAC Information & Knowledge Sharing for the industry professional! ... The refrigerant tubing must be of adequate size, not being undersized to any degree which would drive up the head pressure and lower the suction pressure. 5.) The metering device cannot be …The Two Condenser Head Pressure II Module is designed to work stand-alone by using its OPTIONS dip switch to adjust the Head Pressure setpoint. The Two Condenser Head Pressure II Module is directly connected to the VCM-X Modular E-BUS, VCM-X WSHP E-BUS or SA E-BUS Controller, allowing the Module(s) to receive setpoints from the …How to Check Subcooling. Attach the thermometer to the liquid line. This time, near the condenser. Then take the head pressure in Psi and convert it to the temperature on the pressure/temperature chart. Assuming you are dealing with a R22 system, let’s say the head pressure is 260Psi. This will convert to 120F.20 psia. 10:1 is a compression ratio commonly found in refrigeration applications. If you are thinking about air conditioning, it is often around 3:1 or 4:1. Example 2: 200 psia = 20:1. 10 psia. In this example, the suction pressure drops by 10 psia, which doubles the compression ratio. At this compression ratio, a compressor designed …What is head pressure HVAC? March 25, 2024. Does this question strike your mind; what is head pressure HVAC? Head pressure is normally the pressure that a ... Read More. HVAC. How to install the HVAC system? March 21, 2024. The HVAC is responsible for providing you with the required temperature; it also improves air quality …Check the Condenser Fan. The condenser fan generates airflow through the condenser coil. If the condenser fan doesn’t spin, then the condenser coil won’t reject heat properly and your AC high pressure switch will trip. Check the condenser fan to make sure that it spins when the condensing unit kicks on.Low suction pressure and high head pressure is a condition where there is a decreased refrigerant pressure in the AC system and at the same time a high output pressure in a compressor. This condition is mainly caused by a defective or malfunctioning TXV valve. An expansion valve is a device that regulates the flow of the liquid refrigerant …The fan speed controller keeps the condensing pressure at a steady level by regulating the speed of the fan motors. When pressure is declining, the controller decreases the output voltage, changing the speed of fan motor. The proportional band is a non-adjustable pressure difference between max. and min. pressure where the regulation occurs ...Refrigerant Flow. The high side of an HVAC system is where refrigeration begins. Refrigerant exits the compressor at a high pressure. This marks the start of its journey towards cooling. It travels through condenser coils, where it loses heat and becomes a high-pressure liquid. The low side starts at the metering device.The most common liquid line restrictions are clogged filter-driers, metering device inlet screens, a kinked liquid line, or a TXV with an empty bulb. These very rarely cause high head for more than a short period of time. The most common causes of high head pressure include high load, overcharge, and poor heat rejection (such as from …In fluid mechanics, pressure head is the height of a liquid column that corresponds to a particular pressure exerted by the liquid column on the base of its container. It may also be called static pressure head or simply static head (but not static head pressure). Mathematically this is expressed as: = = where is pressure head (which is actually a …Are you looking to take your HVAC skills to the next level? If so, then an HVAC course online might be just what you need. In today’s fast-paced world, online learning has become i...Posting Permissions. Today customer claims Liebert mini-mate has been locking out on high head pressure once or twice a month, sometimes more often, since it was installed approx. 1 year ago. The company that installed it has come out several times to check it out but found no high pressures.The two most common causes of low head pressure at an air conditioner or heat pump compressor motor are: Refrigerant under-charge, due to a refrigerant leak or improper charge. TXV (TEV) malfunction, over-metering refrigerant. This condition is not likely to occur on smaller air conditioners or heat pumps that use a capillary tube to meter ....